← Engineering & Materials

Unit Converter

Thermal Conductivity Converter

Convert thermal conductivity (λ, k) between SI and US units for insulation and building materials.

Convert thermal conductivity

Result—

Exact definitions are used for each unit. BTU and calorie units are International Table (IT) unless stated.

Your calculation stays in your browser.

Thermal Conductivity Converter examples

The first row is a typical mineral wool value, shown in the Thermal Conductivity Converter in both common US units.

InputExpected result
0.04 W/(m·K)0.2773 BTU·in/(h·ft²·°F)
1 BTU·in/(h·ft²·°F)0.1442 W/(m·K)
1 BTU/(h·ft·°F)1.7307 W/(m·K)

Supported units & limits

Converts values between thermal conductivity units. The temperature in the units is a temperature difference, so °C and K are the same and °F is 5/9 K with no offset. The value must be 0 or more. The conversion does not tell you the conductivity of a material, which depends on density, moisture and temperature, and it is not an R-value; R-value also depends on thickness. Results use floating-point arithmetic and rounding follows the chosen precision. The tool converts units only; it does not check that a value is physically realistic. The Thermal Conductivity Converter expects a conductivity, not an R-value; divide a layer's thickness by its conductivity to get thermal resistance.

Common mistakes

Do not mix the per-inch unit BTU·in/(h·ft²·°F) with BTU/(h·ft·°F): they differ by a factor of 12. A lower conductivity means better insulation, the opposite of R-value, where a higher number is better. Conductivity is a material property, whereas an R-value or U-value describes a layer of a given thickness. Make sure the temperature is an interval and not a reading.

Privacy

Conversions run in your browser. This site does not upload or store the values you enter. We use Google Analytics, loaded through Google Tag Manager, to count page visits and see which tools are used; Google may set cookies for this. The hosting server may keep standard access logs when you load a page.

Conversion guide

Check which unit your data sheet uses

Insulation data sheets use W/(m·K) in most of the world and BTU·in/(h·ft²·°F) in the United States. Convert so that you compare like with like, then combine with thickness to find a resistance. A lower conductivity is better.

Thermal Conductivity Converter FAQ

How do I convert W/(m·K) to BTU·in/(h·ft²·°F)?

Divide the W/(m·K) value by 0.1442279. A conductivity of 0.04 W/(m·K), typical of insulation, is 0.277 BTU·in/(h·ft²·°F).

What is the difference between BTU·in/(h·ft²·°F) and BTU/(h·ft·°F)?

The first is conductivity per inch of thickness and the second per foot, so the per-foot figure is 12 times larger. Use the unit that your data sheet states.

Is thermal conductivity the same as R-value?

No. Conductivity is a material property, and R-value is the resistance of a layer of a given thickness. For a layer, R = thickness ÷ conductivity, so use the R-value to U-value tool for resistances.

Which conductivity unit does the Thermal Conductivity Converter use for insulation datasheets?

European datasheets give λ in W/(m·K), and US datasheets often give k in BTU·in/(h·ft²·°F); the Thermal Conductivity Converter converts between both, plus BTU/(h·ft·°F) and calorie units.