Estimate constant-load runtime from rated capacity, available capacity share, conversion efficiency and battery-side idle power.

Estimate battery runtime under a constant load

Estimated runtime8.64h
Same runtime in minutes
518.4 min
Nominal rated energy
1,200 Wh
Energy assigned to this run
960 Wh
Assumed total battery draw
111.1111111 W

Available share is the fraction of rated capacity between your starting state and chosen reserve. Battery draw = useful W / efficiency + additional battery-side idle W. Keep idle at zero if it is already included in the efficiency assumption. This is a constant-load estimate, not a measured discharge curve.

Your calculation stays in your browser.

Battery Runtime Calculator examples

InputExpected result
100 Ah, 12 V; 100% available; 100% efficient; 60 W; no idle20 h ideal constant-load runtime
100 Ah, 12 V; 80% available; 90% efficient; 100 W; no idle8.64 h estimate
1000 Wh; 100% available; 100% efficient; 100 W + 100 W battery idle5 h estimate
0% capacity available; positive load0 h

Supported units & limits

Capacity is 0–1e12 Ah, mAh, Wh or kWh. Ah/mAh requires nominal voltage 0.000001–1,000,000 V; Wh/kWh ignores the hidden voltage field. Available share is 0–100%; efficiency is greater than 0 through 100%; useful load is greater than 0 through 1e12 W; additional idle is 0–1e12 W. These are arithmetic ranges, not hardware limits. Voltage, efficiency and average real load are assumed constant. Peukert effects, discharge-rate-dependent capacity, temperature, aging, battery cutoff, startup surge and changing loads are not simulated. Choose an available share consistent with your starting state and reserve; this tool does not determine a suitable discharge depth. Floating-point results use selected precision.

Common mistakes

Rated energy is not automatically available energy. Use real load watts rather than VA. Divide useful load by efficiency to find battery-side draw; multiplying load by efficiency would underestimate draw. Idle power here is additional battery-side power, so do not add it again if your measured draw or efficiency already includes it. Entering the inverter output as the load without the efficiency setting makes this calculator overestimate runtime.

Privacy

Conversions run in your browser. This site does not upload or store the values you enter. We use Google Analytics (through Google Tag Manager) to count page visits, and Microsoft Clarity to see how pages are used, such as clicks and scrolling; both may set cookies, and Clarity is set to mask text on the page. The hosting server may keep standard access logs when you load a page.

Conversion guide

Build an energy budget before predicting runtime

Enter the complete pack’s capacity and, when needed, its matching nominal voltage. Set the fraction available for this run. Use average real load watts, a matching conversion efficiency and only additional battery-side idle draw. Review the assumed energy and total draw alongside the duration. For a specific battery, compare with manufacturer discharge data.

Battery Runtime Calculator FAQ

Why can actual runtime differ?

A real battery’s available capacity and voltage can change with discharge rate, temperature and age. Cutoff settings, varying loads and conversion losses also affect delivery.

What should available percentage represent?

It is your assumed share of rated capacity available between the starting state and the reserve you plan to retain. The tool does not infer state of charge or choose a discharge policy.

Why is voltage hidden for Wh and kWh?

Those units already describe energy. Ah and mAh describe charge and need a voltage to estimate nominal energy.

Where does idle power belong?

Enter additional idle draw measured on the battery side. The model adds it after load/efficiency, so it is not divided by load-conversion efficiency again.