Convert an Ethernet frame rate to frame bandwidth and modeled line occupancy using an explicit frame size.

Convert Ethernet frame rate to bandwidth

Result—

Input is a complete Ethernet frame, not an IP packet. Each frame adds 8 byte-times for preamble/SFD and 12 for minimum inter-frame gap. IFG is idle time, not payload bytes. PHY coding and application payload are outside this model.

Your calculation stays in your browser.

Packets per Second to Bandwidth Converter examples

InputExpected result
1000 pps, 1518-byte frame12.304 Mbps line occupancy; 12.144 Mbps frame bits
1 Mpps, 64-byte frame672 Mbps line occupancy
14,880 pps, 64-byte frame9.99936 Mbps line occupancy
1000 pps, 9216-byte frame73.888 Mbps line occupancy

Supported units & limits

Supports 0–1e12 pps, kpps or Mpps and integer complete frame lengths 64–9216 bytes. The 9216-byte limit is a product input cap, not a claim that every link supports jumbo frames. Frame length includes Ethernet header, payload, tags, padding and FCS, excluding preamble/SFD and IFG. This idealized single-direction steady frame stream uses the minimum IFG; no PHY coding, FEC, collisions, additional encapsulation or application-goodput model is applied. Average decimal frame rates are allowed. Large results use floating-point display precision.

Common mistakes

Do not enter a 1500-byte IP packet as a 1500-byte complete Ethernet frame. An untagged Ethernet frame carrying 1500 IP bytes is 1518 bytes including its 4-byte FCS. Some captures omit FCS; account for it before entering length. Include any VLAN tags already in the frame length. IFG is counted as occupied link time and is not data delivered to an application.

Privacy

Conversions run in your browser. This site does not upload or store the values you enter. We use Google Analytics, loaded through Google Tag Manager, to count page visits and see which tools are used; Google may set cookies for this. The hosting server may keep standard access logs when you load a page.

Conversion guide

Use frame sizes from the same accounting layer

Obtain the full Ethernet frame length including FCS, tags and padding. Select the frame-rate unit and enter the average rate. Compare modeled occupancy with a MAC bit-rate capacity in the same direction. At a known MAC bit-rate capacity, divide that capacity by the occupied bits per frame to estimate the maximum steady frame rate.

Packets per Second to Bandwidth Converter FAQ

Does pps mean IP packets here?

The calculation assumes one complete Ethernet frame for each counted packet. Fragmentation, tunneling or other mappings need their actual frame sizes and counts.

Why add twenty byte-times?

The model adds eight for preamble/SFD and twelve for the minimum inter-frame gap. The gap consumes link time even though it is not transmitted payload.

Is line occupancy the application rate?

No. Frame headers, FCS and higher-layer headers are not useful application data. This tool reports Ethernet occupancy and frame bit rate separately.