Unit Converter
COP to EER Converter
Convert between COP, EER and kilowatts of electricity per ton of cooling.
COP to EER Converter examples
Here the COP to EER Converter is applied to typical chiller ratings in COP, EER and kW per ton.
| Input | Expected result |
|---|---|
| COP 3.5 | EER 11.94 · 1.005 kW per ton |
| EER 12 | COP 3.517 · 1.00 kW per ton |
| 0.9 kW per ton | COP 3.908 · EER 13.33 |
Supported units & limits
Converts a single COP, EER or kW per ton value, which must be greater than 0 and at most 1,000,000. The conversion applies at one operating point, for the same conditions for output and input. It is not a conversion for SEER or SEER2, which average performance over a season and use different test conditions, nor for heating COP at other conditions. Results use floating-point arithmetic and rounding follows the chosen precision.
Common mistakes
COP and EER describe the same efficiency in different units, but SEER is a seasonal average and cannot be derived from one COP. A higher COP or EER is better, but a higher kW per ton is worse. Heating COP for a heat pump is a different test from cooling COP. Use matching conditions when comparing values and confirm whether the electrical input includes fans and pumps. Seasonal ratings such as SEER2 come from a different test, so a result from the COP to EER Converter should not be compared with them directly.
Privacy
Conversions run in your browser. This site does not upload or store the values you enter. We use Google Analytics, loaded through Google Tag Manager, to count page visits and see which tools are used; Google may set cookies for this. The hosting server may keep standard access logs when you load a page.
Conversion guide
Compare equipment at the same conditions
Convert both ratings to the same measure and make sure they were taken at the same conditions. Use kW per ton to estimate the electrical power of a cooling load, and remember that fans and auxiliary equipment may not be included. For annual energy use, use seasonal ratings and a proper analysis.
COP to EER Converter FAQ
How do I convert COP to EER?
Multiply the COP by 3.412142. A COP of 3.5 is an EER of 11.94. To go back, divide the EER by 3.412142.
What is kW per ton?
The electrical power needed for each ton of cooling, equal to 3.517 divided by the COP. An EER of 12 is exactly 1 kW per ton. Lower is better.
Can I convert SEER to COP?
Not exactly. SEER is a seasonal average over varying conditions, while COP and EER describe one operating point. A rough guide is possible, but this tool does not claim it.