Battery Charging Time Converter
Estimate charging duration for a chosen state-of-charge interval using average net battery-side current and charge-retention efficiency.
Battery Charging Time Converter examples
These rows show how the Battery Charging Time Converter changes when the SOC window or charge retention changes.
| Input | Expected result |
|---|---|
| 10 Ah; 2 A average; 0→100%; 100% charge retention | 5 h |
| 10 Ah; 2 A average; 20→80%; 100% charge retention | 3 h |
| 10 Ah; 2 A average; 20→80%; 80% charge retention | 3.75 h |
| 10000 mAh; 2000 mA average; 0→100%; 100% retention | 5 h |
Supported units & limits
Capacity is 0–1e12 Ah or mAh; average net battery current is greater than 0 through 1e9 A or mA. Starting and target SOC are each 0–100%, with target no lower than start. Charge-retention efficiency is greater than 0 through 100%. The SOC-to-charge relation is treated as linear against the entered rated capacity. The model uses a supplied average battery-side current and does not predict CC/CV current taper, conditioning, temperature regulation, balancing, termination, changing device load or battery chemistry. Using a maximum CC current as though it were the full-cycle average can understate duration. It does not recommend charge current or a charging profile. Results use floating-point arithmetic with selected precision.
Common mistakes
Adapter-side amperes may differ from battery-side amperes when voltage conversion is involved. Supply the average net current entering the battery after any operating device load. Coulombic charge efficiency is not the same as charger electrical energy efficiency. Do not apply a taper penalty again if the entered average current already includes taper. A percentage-point SOC difference, such as 80−20=60, is used here. Most chargers taper current near full charge, so an average current taken from the label makes the Battery Charging Time Converter too optimistic for the last 20 %.
Privacy
Conversions run in your browser. This site does not upload or store the values you enter. We use Google Analytics, loaded through Google Tag Manager, to count page visits and see which tools are used; Google may set cookies for this. The hosting server may keep standard access logs when you load a page.
Conversion guide
Match average current to the charging interval
Enter rated charge capacity and the start/target SOC interval. Use the average net current at the battery for that same interval and an appropriate charge-retention assumption. Read both retained and terminal input charge to check the estimate. Compare real charge times with the charger and battery’s documented behavior; the tool does not choose operating settings.
Battery Charging Time Converter FAQ
Does this simulate a lithium battery charging curve?
No. It uses an average current supplied by you. Many real charge cycles include constant-current and constant-voltage phases, and current can taper toward the end.
What does charge efficiency mean here?
It is the ratio of charge retained to net charge entering the battery terminals. It is not a charger power-conversion efficiency.
Can I use the charger label’s current?
Only if it represents the average net current at the battery over the interval you are estimating. A maximum output rating or adapter input current is generally a different quantity.
Why is the answer zero when start equals target?
The selected SOC interval requires no additional charge in this arithmetic model. Device checks, balancing or other fixed delays are not included.